The simplest nanocantilever is also the most sensitive

Posted In: Photonics

Monday, April 27, 2009

Loading...
April 27, 2009

Electronmicroscopic image of array (top) and simulation of lightwaves through array (bottom). (Yale University)
As researchers push towards detection of single molecules, single electron spins and the smallest amounts of mass and movement, Yale researchers have demonstrated silicon-based nanocantilevers, smaller than the wavelength of light, that operate on photonic principles eliminating the need for electric transducers and expensive laser setups.

The work reported in an April 26 advance online publication of Nature Nanotechnology ushers in a new generation of tools for ultra-sensitive measurements at the atomic level.

In nanoelectromechanical systems (NEMS), cantilevers are the most fundamental mechanical sensors. These tiny structures—fixed at one end and free at the other—act like nano-scale diving boards that "bend" when molecules "jump" on them and register a change that can be measured and calibrated. This paper demonstrates how NEMS can be improved by using integrated photonics to sense the cantilever motion.

"The system we developed is the most sensitive available that works at room temperature. Previously this level of sensitivity could only be achieved at extreme low temperatures" said senior author Hong Tang, assistant professor of electrical and mechanical engineering in the Yale School of Engineering and Applied Sciences.

Their system can detect as little deflection in the nano-cantilever sensors as 0.0001 Angstroms—one ten thousandth of the size of an atom To detect this tiny motion, the Yale team devised a photonic structure to guide the light wave through a cantilever. After exiting from the free end of the cantilever, the light tunnels through a nanometer gap and is collected on chip.

"Detecting the lightwave after this evanescent tunneling," says Tang, "gives the unprecedented sensitivity."

Tang's paper also details the construction of a sensor multiplex—a parallel array of 10 nano-cantilevers integrated on a single photonic wire. Each cantilever is a different length, like a key on a xylophone, so when one is displaced it registers its own distinctive "tone."

"A multiplex format lets us make more complex measurements of patterns simultaneously—like a tune with chords instead of single notes," said postdoctoral fellow Mo Li, the lead author of the paper.

At the heart of this breakthrough is the novel way Tang's group "wired" the sensors with light. Their technique is not limited by the bandwidth constraints of electrical methods or the diffraction limits of light sources.

"We don't need a laser to operate these devices," said Wolfram Pernice, a co-author of the paper. "Very cheap LEDs will suffice." Futhermore, the LED light sources—like the million LED pixels that make up a laptop computer screen—can be scaled in size to integrate into a nanophotonic-chip—an important feature for this application.

"This development reinforces the practicality of the new field of nanooptomechanics," says Tang, "and points to a future of compact, robust and scalable systems with high sensitivity that will find a wide range of future applications—from chemical and biological sensing to optical signal processing."

Original Release
Abstract

SOURCE: Yale University
JOIN THE DISCUSSION
Rate Article:  Average 0 out of 5
Register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

New To Market

more

P2i showcases liquid repellent nano-coating for hearing aids
P2i showcases liquid repellent nano-coating for hearing aids

At the AudiologyNOW! 2010 show in San Diego next month, UK-based coatings company P2i will display their relatively new Aridion liquid-repellant nano-coating. Designed for exposure to humidity or sweat, the polymer layer is applied by a pulsed ion gas process that lower’s the hearing aid’s surface energy, coaxing water away from delicate components.

Submersible FlowCAM catches particle images and data in-situ and real-time

Fluid Imaging Technologies recently introduced its Submersible FlowCAM particle and cell imaging and analysis system at Ocean Sciences 2010 in Portland, Ore. The remote sensing platform can be used for continuous, unattended monitoring tethered to research vessels or autonomous submersibles.

Tools & Technology

more

Benchtop NMR analyzer
Benchtop NMR analyzer

Oxford Instruments America, Inc.’s Magnetic Resonance Group released the second generation of its MQC analyzers.

Software solution for microarray image analysis

BioDiscovery Inc. released ImaGene 9.0 for microarray image analysis. The new features include improved memory performance for the latest high density arrays, streamlined processing pipeline focused on image quantification and intensity extraction, and new modular design with options to add modules for analysis of gene/miRNA expression or CGH data.

Advertisement

Advertisement