FBI reveals science behind anthrax investigation

Posted In: General Sciences

Thursday, August 21, 2008

Loading...


They have worked for almost seven years in secret.

Bacillus anthracis spores as viewed in SEM (left) and TEM (right).

Most people did not know that the work in Ray Goehner's materials characterization department at Sandia National Laboratories was contributing important information to the FBI's investigation of letters containing bacillus anthracis, the spores that cause the disease anthrax. The spores were mailed in the fall of 2001 to several news media offices and to two U.S. senators. Five people were killed.

Sandia's work demonstrated to the FBI that the form of bacillus anthracis contained in those letters was not a weaponized form, a form of the bacteria prepared to disperse more readily. The possibility of a weaponized form was of great concern to investigators, says Joseph Michael, the principal investigator for the project. This information was crucial in ruling out state-sponsored terrorism.

In fall of 2001, the FBI considered how to best investigate the anthrax letters. The agency convened two blue ribbon exploratory panels, and Sandia's name came up during both panels for its expertise in electron and ion microscopies and microanalysis over the range of length scales from millimeters down to nanometers. The first spore material from the letters arrived at Sandia in February of 2002.

Sandia faced some uncertainty in working on this type of investigation. Researchers signed nondisclosure agreements and agreed to make themselves available to government agencies on short notice when called to give information.

Joseph Michael, transmission electron microscopy (TEM) lab owner Paul Kotula, and a team of roughly a dozen others examined more than 200 samples in those six and a half years. They received samples from the letter delivered to the New York Post, to former Sen. Tom Daschle (D-S.D.), and to Sen. Patrick Leahy (D-Vt.). The samples looked different, in part because of how the samples were prepared, which made examination initially difficult.

When bacillus anthracis spores are weaponized, the spores are coated with silica nanoparticles that look almost like lint under the microscope. The "lint" makes the particles "bouncier" and less likely to clump and fall to the ground. That makes the spores more respirable and able to do more damage, says Michael. Weaponization of the spores would be an indicator of state sponsored terrorism.

Sandia's material characterization analysts (from left to right) Joseph Michael, Paul Kotula, and manager Ray Goehner.

"Initially, scanning electron microscopy [SEM] conducted at another laboratory, showed high silicon and oxygen signals that led them to conclude that the spores were a weaponized form, says Kotula. "The possible misinterpretation of the SEM results arose because microanalysis in the SEM is not a surface-sensitive tool," says Kotula. "Because a spore body can be 1.5 to 2 microns wide by 1 micron long, a SEM cannot localize the elemental signal from whole spore bodies."

Using more sensitive transmission electron microscopy (TEM), Kotula and Michael's research indicated that the silica in the spore samples was not added artificially, but was incorporated as a natural part of the spore formation process. "The spores we examined," Kotula says, "lacked that fuzzy outer coating that would indicate that they'd been weaponized."

Sandia's work was the first to actually link the spore material in the New York Post, the Daschle and the Leahy letters. The elemental signatures and the locations of these signatures, while not indicating intentional weaponization, did show that the spores were indistinguishable and therefore likely came from the same source. That conclusion was corroborated a few years later by the DNA studies.

The materials characterization lab serves as a materials analysis resource for a diverse collection of projects. The lab plays an important role in stockpile surveillance, supporting Sandia's nuclear weapons mission.

Michael was recently released from his nondisclosure agreement and flown to Washington, D.C., to participate in press conferences at FBI Headquarters along with several members of research teams who'd been asked to examine other aspects of the anthrax case.

The FBI was pleased with Sandia's work, says Michael.

Sandia National Laboratory, http://www.sandia.gov/

SOURCE: Sandia National Laboratory

JOIN THE DISCUSSION
Rate Article:  Average 0 out of 5
Register or log in to comment on this article!

0 Comments

Add Comment

Text Only 2000 character limit

Page 1 of 1

New To Market

more

P2i showcases liquid repellent nano-coating for hearing aids
P2i showcases liquid repellent nano-coating for hearing aids

At the AudiologyNOW! 2010 show in San Diego next month, UK-based coatings company P2i will display their relatively new Aridion liquid-repellant nano-coating. Designed for exposure to humidity or sweat, the polymer layer is applied by a pulsed ion gas process that lower’s the hearing aid’s surface energy, coaxing water away from delicate components.

Submersible FlowCAM catches particle images and data in-situ and real-time

Fluid Imaging Technologies recently introduced its Submersible FlowCAM particle and cell imaging and analysis system at Ocean Sciences 2010 in Portland, Ore. The remote sensing platform can be used for continuous, unattended monitoring tethered to research vessels or autonomous submersibles.

Tools & Technology

more

Benchtop NMR analyzer
Benchtop NMR analyzer

Oxford Instruments America, Inc.’s Magnetic Resonance Group released the second generation of its MQC analyzers.

Software solution for microarray image analysis

BioDiscovery Inc. released ImaGene 9.0 for microarray image analysis. The new features include improved memory performance for the latest high density arrays, streamlined processing pipeline focused on image quantification and intensity extraction, and new modular design with options to add modules for analysis of gene/miRNA expression or CGH data.

Advertisement

Advertisement